Skip to content

Troubleshooting

Start here

Help ▸ Collect Diagnostics… bundles the runtime, versions, detected GPU, environment state, and recent session log into one file. Attach it to any bug report — it usually contains the answer.

The Notifications panel keeps the messages that toasts showed and dismissed while you were looking elsewhere.

Video won't play

The codec isn't supported. WebCodecs decodes 8-bit H.264, HEVC, VP8, VP9, and AV1, plus MJPEG. Everything else — MPEG-½, Xvid/DivX, WMV, VC-1, and 10-bit H.264/HEVC — needs converting.

  • Desktop — the app offers to transcode it once and caches the result.
  • Browser — convert it yourself:

    ffmpeg -i input.avi -c:v libx264 -pix_fmt yuv420p output.mp4
    

    -pix_fmt yuv420p is the part that forces 8-bit.

The file moved. Use File ▸ Replace Videos ▸ (video) to re-point it.

The project opens but frames are blank

The .slp references videos that aren't where it expects. Either replace the video paths as above, or work from a .pkg.slp, which carries its frames inside the file.

Training won't start

  • "Label at least one frame before training" — training needs user-labeled frames. Predictions don't count until you accept them.
  • sleap-nn not detected — open the Environment panel and install it. See Environment setup.
  • In the browser — there is no local training. Connect to a remote worker.

Training runs out of memory

The Training panel's Estimated Memory Usage breakdown shows where it goes. Reduce, roughly in this order: batch size, crop size, input scaling, model filters. Switching Data Pipeline from memory to stream also helps when the dataset itself is the problem.

Predictions look wrong everywhere

Before retraining, run Analyze ▸ Label Quality Check. A systematic left/right swap or a chain-order error in the labels produces exactly this, and no amount of extra training fixes it. See Label Quality Check.

Predictions are cut off at the edges

The crop is too small. Re-derive it from Analyze ▸ Instance Size Distribution at the rotation setting you train with, and check your anchor part is central and reliably visible.

Identities keep swapping

That's a tracking failure, not a pose failure. Cmd+T transposes two instances' tracks. To find where it goes wrong, set the seekbar header to Min Centroid Proximity or Tracking Score and look at the dips, and use Cmd+E to walk track spawn frames. See Tracks.

Can't connect to a worker

  • Check the worker is running: sleap-rtc serve on the GPU machine. A worker that isn't shows Offline in the Connect window.
  • This pairing code expired — run sleap-rtc pair again and paste the new code.
  • This ticket has no worker address — fill in Worker address under the code, for example ws://192.168.1.42:9631. This computer must be able to reach that address.
  • Has a new identity — the address now answers as a different worker (it was reinstalled, or the IP moved). Click Re-pair on its card and paste a fresh code from sleap-rtc pair.
  • Reconnecting… — the app retries on its own. Jobs keep running on the worker meanwhile.
  • Busy is not an error: the worker is running a job, and new jobs wait in its queue.
  • If the worker can't see your videos, use Locate on worker…, or check the Data access tab for the folders it shares. See Remote Compute.

Save is slow

Saving a large .pkg.slp with embedded images uses a streaming writer that does many small operations. Over a network share this is slow. Save locally, then copy.

macOS refuses to open the app

macOS builds from v0.1.2 on are signed with an Apple Developer ID and notarized, so a downloaded .dmg opens normally.

The block only affects older copies (v0.1.1 and earlier) and builds you made yourself, which aren't notarized. For those, clear the quarantine flag on the .dmg before opening it:

xattr -dr com.apple.quarantine ~/Downloads/SLEAP_*.dmg

Or install with the installer script, which clears the flag for you.

The update won't apply

  • Linux — only the .AppImage payload can be replaced in place without root. If you installed the .deb or .rpm, update through your package manager.
  • Windows — the installer refuses to overwrite a running copy. Quit the app first.

Something else